The Journal of Experimental Medicine
BioLegend: New Th17, Treg Tools
  Home | Help | Feedback | Subscriptions | Archive | Search | Table of Contents

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Services
Right arrow Email this article
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new content in the JEM
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hinz, C. F.
Right arrow Articles by Lepow, I. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hinz, C. F., Jr.
Right arrow Articles by Lepow, I. H.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
The Journal of Experimental Medicine, Vol 113, 177-192, Copyright, 1961, by The Rockefeller Institute


ARTICLE

STUDIES ON IMMUNE HUMAN HEMOLYSIS : I. THE KINETICS OF THE DONATH-LANDSTEINER REACTION AND THE REQUIREMENT FOR COMPLEMENT IN THE REACTION



Carl F. Hinz Jr. M.D.1, Mary E. Picken 1, and Irwin H. Lepow M.D.1

1 From the Department of Medicine, School of Medicine and the Institute of Pathology, Western Reserve University, Cleveland

The Donath-Landsteiner reaction was studied using low and high titer antisera and purified antibody, normal and PNH erythrocytes, and human serum complement.

The requirement for complement in both the cold and warm phases of the reaction depended upon the level of antibody used and the sensitivity of the cells to hemolytic antibodies. Complement was not necessary in the cold phase using PNH cells and a potent source of antibody, but complement was required to be present at some stage if hemolysis were to occur.

Optimal conditions for the cold phase were at 1°C. for 30 minutes at pH 7.4. Ca++ ions were required. Hemolysis in the warm phase occurred within one minute, was optimal at 32°C., and required Mg++.

The relation of these observations to previous reports is discussed with respect to discrepant observations on the nature of the Donath-Landsteiner reaction.

Submitted on August 11, 1960


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?




  Home | Help | Feedback | Subscriptions | Archive | Search
TABLE OF CONTENTS